Biasi Boiler Error 04

error 04 boiler biasi

What is the fault of error 04 Biasi affecting your boiler?

Have you encountered the error code 04 on your Biasi boiler and you're unsure of what it means or how to resolve it? Don't worry; we're here to explain everything you need to know about this issue and how to quickly and easily find a solution.

The error code 04 on Biasi brand boilers indicates that there's an issue with the water supply to the boiler. This could be caused by several factors, such as:

  • A water leak in the heating circuit or at the filling tap
  • Water pressure that is either too low or too high in the boiler
  • An obstruction or dirt in the water inlet filter or valves
  • A faulty pressure sensor or the boiler's electronic board

Any of these causes can prevent the boiler from operating correctly and trigger the error code 04 on your appliance. Fortunately, this type of error is fixable, so stay with us and keep reading. We'll find the solution!

How to solve the error 04 of the Biasi boiler?

This error code 04 on Biasi boilers could be considered quite easy to resolve. To fix it, you can follow these steps provided below:

  1. Restart the boiler to reset the sensors: This is done by turning off the boiler, disconnecting it from the power supply, and waiting a few minutes before reconnecting it. Turn it back on and check if the error code has disappeared.
  2. Check the water supply: Make sure you have a clean and stable water flow to supply this vital liquid to your boiler. If the boiler is not receiving water from your home's supply, then this is likely the cause of the error. Also, ensure that there are no leaks in the hose leading from your supply to the boiler.
  3. Inspect for any water leaks in the circuit: Checking for water leaks is crucial when encountering this error code. Verify that there are no leaks anywhere in the water heating circuit. Thoroughly inspect hoses, joints, and all connections. If you find a leak, you'll need to repair it as soon as possible.
  4. Check the water pressure in the boiler: The water pressure should be between 1 and 1.5 bar. If it's below this range, open the filling tap until the pressure increases. If it's above this range, open a radiator or a hot water tap until the pressure decreases.
  5. Clean the water inlet filter and valves: These components can accumulate dirt, sand, limescale, or something that obstructs the water flow. To clean them, you should shut off the water supply, carefully disassemble them, and clean them with a soft-bristle brush or a damp cloth. You can use warm water and a bit of vinegar to assist with cleaning.
  6. Check the pressure sensor and the boiler's electronic board: These components can fail due to a manufacturing defect or overheating. To inspect them, turn off the boiler, disconnect it from the power source, and open the front panel. The pressure sensor is typically located near the pressure gauge and has two connected cables. The electronic board is usually behind the LCD display and has several connected cables. If you see any signs of burning, damage, or disconnection, you'll need to replace them with new ones.
  7. Go over everything we've mentioned previously: If the problem persists, repeat the previous steps. Double-check everything, perform secondary inspections, and ensure you follow each step precisely.
  8. Seek assistance from Biasi's technical support to resolve the issue: If, after following all the previous steps, the error code 04 continues to appear, it indicates a more serious problem that requires the intervention of a qualified professional. If you've reached this point, it's time to call Biasi's technical service and schedule an in-depth inspection of your boiler.

In summary, this issue in Biasi boilers is due to a problem with the water supply. An error code 04 that can be resolved quickly and easily by following the steps we've detailed previously and summarized below:

  1. Restart the boiler to reset the sensors
  2. Check the water supply to the boiler
  3. Inspect for any water leaks in the circuit or at the tap
  4. Verify the water pressure in the boiler and adjust it if necessary
  5. Clean the water inlet filter and valve
  6. Inspect the sensor and electronic board and replace them if damaged
  7. Repeat the previous steps if it doesn't work
  8. Contact Biasi's technical service if nothing works

We hope this article has been helpful, and you've been able to resolve the error code 04 on your Biasi boiler. Remember that regular maintenance can help prolong your boiler's lifespan, allowing you to enjoy its benefits for a longer time. Goodbye for now!