Error 10 Immergas Boilers
Index of contents
What does this failure that affects the Immergas boiler want to tell us?
Boilers play an essential role in our home when it comes to keeping our home warm and comfortable. However, like any other appliance, they can experience faults that negatively affect their operation, including those from the Immergas brand. Error code 10 is a message that indicates something is not right with the boiler pressure. But this error code can be more than just a number; it's a warning sign for us to take action and avoid bigger problems in the future.
This fault affecting Immergas boilers is triggered when the device detects insufficient water pressure for its proper operation. This can be due to various reasons, from a simple water leak to a more complex problem in the safety valve. Identifying the exact cause of the problem is important so that you can find an appropriate solution to this problem, thus ensuring that our boiler operates efficiently and safely.
These are the possible causes that can lead to this problem in Immergas boilers:
- Low gas pressure: If the gas pressure is less than 1.2 bar, the boiler cannot operate properly. So you will need to investigate why this pressure has decreased and correct the fault.
- Water leaks in the circuit: A leak can reduce internal pressure and affect the performance of the boiler, causing various errors to appear on its screen.
- A defective circulation pump: A pump that is not functioning correctly can prevent proper water circulation through the entire circuit of your boiler.
- A damaged safety valve: A safety valve in poor condition can release pressure and cause the error to appear on your boiler's screen.
Now that we have identified the causes of this problem, let's see what solutions you can apply to continue using your boiler normally.
Can a solution be found for error code 10 in the Immergas boiler?
We have prepared for you a list of possible solutions to this fault that appears on your boiler's screen. Please take note of each of these steps, follow them to the letter, and do not skip any, as they are all important:
- Turn off and disconnect the boiler may help solve the problem, as it resets its sensors: We can start first with the easiest and simplest of all steps, which is to perform a boiler reset. To do this, you have to completely turn off your boiler and disconnect it from the power outlet for a few minutes. Wait for at least 15 minutes and reconnect the boiler. Turn it on and now check if this error has disappeared. If the problem persists, then you will have to continue with the other steps we have provided below.
- Check that the water supply is active and functioning at full capacity: Open the other faucets in your home or office to check that you have the water supply activated. If you have a water supply cut, contact the water company to confirm if the cut was due to a billing problem or scheduled maintenance in your area. Also, check the shut-off valve that supplies water, both the general one for your entire home or office, and the one that supplies only the boiler. If these valves are halfway open, please open them completely so that the water supply is smooth and constant to your boiler.
- Adjust the water pressure and make sure it is set according to the manufacturer's specifications: Check that the water pressure is correct; it may lack pressure and you may need to adjust the pressure gauge for this. This pressure should be between 1.2 bar minimum and 1.5 bar maximum, but these values could change depending on the model and capacity of your boiler. Check the manufacturer's manual carefully before making such changes and changes in water pressure. Once you have corrected the water pressure, check if the error has disappeared.
- Check the circulation pump of your Immergas boiler: Make sure the pump is working properly and not obstructed by anything. If necessary, remove it from the boiler and perform preventive maintenance on it. If you have knowledge of electronics, check it with a multimeter and make sure it has good continuity in the connection to the PCB electronic board of your boiler. Also, check that the wiring that communicates this pump is in excellent condition.
- Evaluate the safety valve of your Immergas boiler: Make sure the valve is not releasing pressure unnecessarily and/or leaking. If the valve is damaged, it may be necessary to replace it with a new one, but before doing so, you can try to perform a small preventive maintenance on it. Disassemble the valve and clean it with water and a little vinegar, use a bristle brush to clean it well, especially in the holes. Let it dry well and proceed to reassemble it in your boiler. Now check if with this procedure you have been able to solve the problem you had in the boiler.
- Check the entire water circuit of your boiler for unwanted leaks: Check that the boiler does not have any type of leak in the entire water circuit. To be able to verify this, you will have to check the hoses, gaskets, connections, filters, and valves, that is, everything. Check everything and if you find any type of leak, make the necessary repairs or replace the components and parts affected by new ones to avoid leaks in the future.
- If the problem with your boiler persists, carefully review each step we have explained in this article: You don't have to get discouraged, make sure you haven't skipped any steps mentioned in this guide of tips. If you still cannot find the solution, it is time to seek help from an expert in the field who can help you. A qualified professional or Immergas's official technical service can help you diagnose and solve the problem accurately.
- If the problem persists, don't worry, because the experts have the right solution: A qualified technician or Immergas's official technical service will help you solve the fault in your Immergas boiler in record time. They have the necessary experience and knowledge, along with the tools and original spare parts to address this situation in the best possible way, ensuring an effective repair. You can contact them by phone and schedule an appointment for them to visit you at home. Don't hesitate to seek professional help to get your boiler back to working properly!
In summary, to resolve error code 10 on Immergas boilers, you have to follow all the steps we have described in this guide of tips. This fault is due to low pressure in the boiler circuit, and its causes can be the following: low gas pressure, water leak in the circuit, damaged circulation pump, and/or the safety valve that is damaged or dirty. Remember that if you cannot solve the problem yourself, you can always rely on Immergas's technical support to find a solution to this problem. Don't get discouraged and focus on fixing your boiler. Thank you very much for reading us this far, and good luck with the repairs!