What is the failure of the E3 error Daikin affecting your air conditioner?
Daikin air conditioners have become very popular in the market, all thanks to their good quality equipment and acceptable performance. However, like any electronic device, these units can experience errors in their operation and/or wear in their components and parts.
The E3 error code in Daikin air conditioners indicates that there is a problem with the high-pressure switch, a sensor that detects the refrigerant pressure in the system. The good news is that in some cases, you can resolve this issue yourself. Stay with us and keep reading to find out how!
First, we need to identify the possible causes that can trigger the E3 error code on your Daikin air conditioner before we can discuss how to potentially resolve the problem:
- High pressure in the refrigeration system: The high-pressure switch may have been activated due to pressure overload.
- Faulty high-pressure switch: The sensor may be dirty, damaged, or malfunctioning.
- Leakage in the refrigeration circuit: Refrigerant gas leakage can cause low pressure and trigger the error.
- Obstructions caused by a dirty or damaged air filter: A dirty filter can affect airflow and lead to increased pressure.
- Issues with the electronic PCB board: The board that controls the air conditioner's operation could be faulty.
All of these factors can cause an E3 error code to appear on your Daikin air conditioner. However, this issue may be resolved, and we'll explain how you could potentially fix it.
How could you fix the E3 error of the Daikin air conditioner?
We have prepared for you a list of possible solutions for the E3 error code on your Daikin air conditioner. Don't overlook any of them and take note of each:
- Turn off and unplug the air conditioner from the power source to reset its sensors: Let's start with the easiest and simplest solution, which would be to perform a reset of the air conditioner. To do this, simply turn off the air conditioner and unplug it from the power source for a few minutes. Once the time has elapsed, reconnect the unit and turn it back on to see if the E3 error code has disappeared.
- Check your Daikin air conditioner filter to ensure it is clean and in good condition: Open the air conditioner cover and locate the filter, carefully remove it, and proceed to maintain it. You can use a soft-bristled brush, water, and soap to clean it. Avoid applying too much force while cleaning to avoid damaging the filter or the dust-retaining fabric, but apply enough force to carefully remove all trapped dirt. Once cleaned, dry it thoroughly and place it back in position, close the air conditioner cover, and turn it on to see if the E3 error code reappears.
- Inspect the refrigeration circuit pipes for leaks and/or obstructions: Start by visually inspecting the pipes for damage such as dents, cracks, cuts, or any pronounced bends. Look for oil stains, as these could indicate a possible leak, and pay close attention to the joints and elbows, as these components are most prone to leaks. If you want to perform this procedure thoroughly, you will need to use a pressure gauge to check the pressure of the pipes and your air conditioner's circuit. Also, observe the ventilation grilles and ensure that the air comes out with sufficient force. If the airflow is weak or uneven, there may be a blockage in the circuit or your air conditioner may need thorough preventive maintenance to remove and clean all accumulated dust.
- If the problem persists, please repeat all the previous steps and make sure to follow each one precisely: If the above solutions do not work, there may be an issue with the high-pressure switch, a leak in the refrigeration circuit, or a problem with the electronic PCB board that is more complicated to fix. However, we encourage you to repeat all the aforementioned steps to completely rule out that the issue is more severe than initially thought. If the problem persists, then it would be best to have experts address this issue.
- Call Daikin's technical service and request a home visit for a more thorough inspection: A qualified technician can diagnose the problem accurately and efficiently. That's why we encourage you to call Daikin's technical service for an appropriate solution. We are confident that you will be in very good hands.
In summary, the E3 error code in Daikin air conditioners can have various causes, but the most probable one is a faulty high-pressure switch. You can attempt to resolve this issue yourself by following the steps outlined in this article. If you are unsuccessful, contact an authorized Daikin technical service for professional and qualified assistance.
Tips to prevent the E3 error code from appearing on your Daikin air conditioner
- It's always recommended to consult the manufacturer's manual for your Daikin air conditioner to get specific information about your model.
- If you don't feel confident to perform any of the solutions on your own, it's best to call Daikin technical support or a professional technician who is qualified in the field.
- Remember that good preventive and proper maintenance can help prevent such uncomfortable situations with your Daikin air conditioner.
- Always ensure that the installation of your air conditioner is done by a qualified professional, as the most common problems with these devices are caused by leaks in the circuit or improper installation.